Technical
- Provides time legally traceable to UTC
- Synchronizes PC to ±2 milliseconds of GPS reference
- Provides millisecond accuracy to Windows and Linux applications
- Fully configurable time zone and daylight saving time offsets
- PCIe revision 2.0 - slot compatible X1 through X16
- LED status indicator
Specifications
HOLDOVER ACCURACY
• With loss of power or time reference syncronization,
device reverts to an internal battery-backed real-time
clock chip with accuracy of ±1min/year
SUPPORTED DRIVERS
• Windows XP (32 bit)
• Windows 7/8/10 (32 & 64 bit)
• Windows Server 2003 R2/2008 R2/2010 R2/2012
R2/2016
• Linux
SOFTWARE
• API software development kit and documentation is
provided for designers
• Windows OS requires Net Framework 4.0 and a
Windows Visual Studios C++ to be installed
PHYSICAL
• Length: 6.6 in (167.6 mm), Height: 2.712 in
(68.8 mm)
• Low profile card and bracket standard; Full height
bracket included
OPERATING PARAMETERS
• Temperature: 0 to 60 °C
• MTBF: 1,570,000
All calculated using Fixed/Ground Mil HDBK 217F assumption
COMPLIANCE
• FCC, ROHS, CE Marked, ANSI
ANTENNA OPTIONS
• Basic antenna package includes magnetic GPS
antenna and 15 ft (5 m) of cable
• Standard anttenna package includes outdoor GPS
antenna, mounting kit, and 50 ft (15 m) of cable
HIGH-STABILITY OSCILLATOR OPTIONS
• HSO-1 with TCXO provides accuracy of ± 3
seconds/year
• HSO-2 with OXCO provides typical stability of ±
250ms/year after 30 days of aging
Ordering information
There are a range of options available. Please contact Sarsen to discuss your project requirements.