TOTAL: £0.00
home

email


Products

GMR1000 Master Clock


Overview

1U Rackmount Multifunctional Master Clock

The GMR1000 is a compact master clock that can reference a variety of timing sources and provide a range of outputs including NTP, IEEE1588 PTP, IRIG-B, SMPTE, 10Mhz, 1PPS and more.  

The base model includes both NTP server and client functionality compatible with IPv4/IPv6 networks and offers AES 256 Secure-Socket-Host SSH encryption for secure communications.

The device can act as a IEEE1588v2 PTP grandmaster or slave clock, time code generator, NENA time server, frequency generator and more. 

Technical

Standard Inputs
  • NTP client via RJ45 10/100 Mb Ethernet (dual-port)
  • NMEA 0183 via RS232/422 or USB
  • NENA format 0,1,8 via RS232/422 or USB
  • Internal high-stability TCXO oscillator ± 3 sec./year
  • Configuration via USB or Ethernet

Standard Outputs
  • NTP server with 10/100 Mb Ethernet
  • NMEA 0183 via RS232/422 or USB
  • NENA format 0,1,8 via RS232/422 or USB

General
  • Size: 6.44 x 4.06 x 1.44 in (16.35 x 10.32 x 3.65 cm)
  • Weight: 16oz (455g)
  • Temperature: 0 to 60°C
  • 6-Digit display
  • Programmable relay closure - one event per day with NO/NC dry contact relay
  • Relay alerts loss of sync by default
  • WinDiscovery configuration software included
  • Telnet/SSH communication
  • IPv4/IPv6 compatible
  • SNMP with custom MIB
  • FCC, CE Marked, ROHS, ANSI

Specifications

FEATURES

Standard Inputs/Reference Sources

  • NTP client via RJ45 10/100 Mb Ethernet
  • NMEA 0183 via RS232/422 or USB
  • NENA format 0,1,8 via RS232/422 or USB
  • Internal high-stability TCXO oscillator ± 3 sec./year
  • Configuration via USB or Ethernet
 

Input Options

  • GPS or GPS/GLONASS receiver
  • Time codes: IRIG-B0 (DCLS), IRIG-B1 (AM), IRIG-A0 (DCLS), IRIG-A1 (AM), IRIG-E0 (DCLS), IRIG-E1 (AM), SMPTE 12M, 309M, 24/25/30 fps and 29.97 drop frame
  • Internal high-stability OCXO oscillator ± 0.25 sec/year
  • VITC input
  • Synchronizing signals: PPS, PPM, PPH
  • IEEE 1588 Precision Time Protocol
 

Standard Outputs

NTP server with 10/100 Mb Ethernet
NMEA 0183 via RS232/422 or USB
NENA format 0,1,8 via RS232/422 or USB


Output Options

  • Time codes: IRIG-B0 (DCLS), IRIG-B1 (AM), IRIG-A0 (DCLS), IRIG-A1 (AM),
  • IRIG-E0 (DCLS), IRIG-E1 (AM), SMPTE 12M, 309M, 24/25/30 fps
  • and 29.97 drop frame
  • 5V at 20mA Pulse Per Second (PPS)
  • Programmable Pulse Output (PPO)
  • 10MHz sine wave
  • IEEE 1588 Precision Time Protocol
 

Other Features

  • Internal TXCO maintains time during loss of external sync within ± 3 seconds/year
  • WinDiscovery configuration software included
  • Fully configurable offsets for time zone and DST
  • Programmable relay closure - one event per day with NO/NC dry contact relay
  • Relay alerts loss of sync by default
  • Telnet/SSH communication
  • SNMP with custom MIB
  • IPv4/IPv6 compatible
 

Other Options

  • DB9 breakout adapter
  • Six-digit display
  • DIN rail mount available
 

Power, Physical Dimensions, Operating Parameters

  • DC input (9-28 VDC)
  • Includes external 24VDC wall mount power supply with locking DC plug
  • Size: 6.44 x 4.06 x 1.44 in (16.35 x 10.32 x 3.65 cm), Weight: 16 oz (453.6 g)
  • Temperature: 0 to 60°C
  • Humidity: Up to 90% (non-condensing)
 

Compliance

  • FCC, ROHS, CE Marked, ANSI

Technical documents

Ordering information

There are a range of options available. Please contact Sarsen to discuss your project requirements. 